- For
Doors - 1 3/4" thick standard 4 1/2" minimum
stile width for single or double door application using
standard 239 strike and pull or lever trims.
-
Chassis - Steel (Panic Grade), steel (Fire Grade)
- Cover
- Covers stock hollow metal doors with 161
cutout.
-
Mounting - Furnished standard with wood and
machine screws. Available with thru bolts on request.
Thru bolts are included and standard packaging on
fire rated devices.
- End
Cap - Steel construction.
- Hand
- Non handed, center hub.
|
-
Latch Bolt -
Stainless steel 3/4" throw.
-
Spring - Stainless steel throughout.
- ANSI
Standard - A156.3, Grade 2
- Rail
Assembly - Heavy gauge steel, painted.
-
Strike - 239 packed standard.
-
Dogging Feature - Allen-type key furnished
standard on non-fire labeled devices.
- UL
and ULC Listed - 5000 Series for panic. F5000
Series for fire exit hardware for all types of 3' x 7'
single doors and 6' x 7' double doors for up to 3 hour
fire labeled installations, conforms to standards UL10C
and UBC 7-2-1997 codes.
-
Finish - Aluminum (alum), US32D (Stainless
Steel).
|